FS#13767 — FS#19292 — Liens internes BHS <> EU

Attached to Project— Network
Modernization
Whole Network
CLOSED
100%
Following the issue with http://status.ovh.net/?do=details&id=13766 and the OSPF flap, we will optimize the actuel routing by moving the half of the capacity to the *-g2-a75. We will take: 2x10GB from the 4x10GB SBG<>BHS and move those links to sbg-g1-a75 <> bhs-g1-a75. 1x10GB from the 2x10GB GRA<>BHS and move those links to gra-g1-a75 <> bhs-g1-a75. 1x10GB from the 2x10GB RBX<>BHS and move those links to rbx-g1-a75 <> bhs-g1-a75.

This will allow us the have a robust redundancy of the chassis on internal link BHS <> EU.

Date:  Friday, 22 July 2016, 19:22PM
Reason for closing:  Done
Comment by OVH - Friday, 22 July 2016, 19:22PM

The maintenance has been completed.